MITSUBISHI A1SD70 User's Manual (Hardware) PDF
Product model: A1SD70
Name: Positioning Module
Brand: MITSUBISHI
Sort: Hardware User's Manual
File language: English
3C-2V/5C-2V coaxial cable single bus remote I/O network (remote I/O station).
Q mode.
When the programmer input programinto the user program memory,
Then CPU according to the function of the system (the system program memory to explain the compiler),
Translate the user program into PLC internally recognized by the user to compile the program A1SD70 PDF.
Input status and input information input from the input interface,
CPU will be stored in the working data memory or in the input image register A1SD70
And then combine the data and the program with CPU.
The result is stored in the output image register or the working data memory,
And then output to the output interface, control the external drive A1SD70 PDF.
Semiconductor circuit with memory function.
System program memory and user memory.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program to do the compiler to compile the process of interpretation A1SD70 PDF.
Read only memory. Manufacturers use, content can not be changed, power does not disappear.
User memory: user program storage area and work data storage area.
Composed of random access memory (RAM). User use.
Power cut off. Commonly used efficient lithium battery as a backup power supply, life is generally 3~5 years MITSUBISHI User's Manuaal A1SD70 Manual. SI/QSI/H-PCF/ wide H-PCF optical cable double loop PC (control station / common station) / remote I/O network (remote master station).
Switch volume control is designed to,
According to the current input combination of the switch quantity and the history of the input sequence,
So that PLC generates the corresponding switching output,
In order to make the system work in a certain order MITSUBISHI User's Manual.
So, sometimes also known as the order control.
And sequential control is divided into manual, semi-automatic or automatic MITSUBISHI User's Manual.
And the control principle is decentralized, centralized and hybrid control three.
The length of time required to execute the instruction, the length of the user''s program, the type of instruction, and the speed of the CPU execution are very significant,
Generally, a scanning process, the fault diagnosis time,
Communication time, input sampling and output refresh time is less,
The execution time is accounted for the vast majority of.
The response time of PLC is the interval between the time of the change of the external output signal of the PPLC and the time of the change of the external output signal which is controlled by it,
Lag time, this is the time constant of the input circuit,
The time constant of the output circuit, the arrangement of the user statement and the usse of the instruction,
The cycle scan mode of PLC and the way of PLC to refresh the I/O and so on A1SD70 Manual A1SD70 User's Manual.
This phenomenon is called the I/O delay time effect.
Related products
MITSUBISHI
Positioning control module
A1SD75P3-S3
MITSUBISHI Positioning control module A1SD75P3-S3
Axis of control: 3 axis linkage, 3 axis
MITSUBISHI
Melsecnet interface module
A1SJ71AT21B
MITSUBISHI Melsecnet interface module A1SJ71AT21B
Cale type: twisted pair cale. The func
MITSUBISHI
Serial communication module
A1SJ71QC24
MITSUBISHI Serial communication module A1SJ71QC24
RS-232 1 channel. RS-422/485 1 channel.
MITSUBISHI
Input module
A1SX20EU
MITSUBISHI Input module A1SX20EU
Input type: AC. Input points: 16 points.