MITSUBISHI A0J2HCPUR21 Programming Manual (Common Instructions) PDF
Product model: A0J2HCPUR21
Name: Programmable Logic Controller
Brand: MITSUBISHI
Sort: Common Instructions Programming Manual
File language: English
Optional features of memory card (A/FX compatible).
2MB extended memory.
Applicable models: A985 (-V) /975/970/A960GOT (-B) /A956WGOT. Input points: 16 points A0J2HCPUR21 PDF.
Input voltage and current: 3/7mA DC12/24V.
Input response time: 10ms.
16 point /1 a public side.
Positive pole sharing.
Output points: 12 points.
Output voltage: DC24V/AC240V, 2A/1 point, 5A/1 common end.
Output response time: 12ms A0J2HCPUR21
Output type: relay output.
8 point /1 a public end, 3 point /1 a public end.
Independent contact.
36 point terminal station.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points A0J2HCPUR21 PDF A0J2HCPUR21 PDF A0J2HCPUR21 Manual.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process MITSUBISHI Programming Manual .
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor MITSUBISHI Programming Manual .
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal MITSUBISHI Programming Manual A0J2HCPUR21 Programming Manual .
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general, a reversible DC drivee system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points A0J2HCPUR21 Manual.
Related products
MITSUBISHI
CPU unit
A0J2HCPU
MITSUBISHI CPU unit A0J2HCPU
Input and output points: 480 points. Inp
MITSUBISHI
CPU unit
A2CCPUR21
MITSUBISHI CPU unit A2CCPUR21
Input and output points: 512 points. Inp
MITSUBISHI
CPU unit
A1NCPUR21
MITSUBISHI CPU unit A1NCPUR21
Input and output points: 256 points. Inp
MITSUBISHI
CPU unit
A2ACPUR21
MITSUBISHI CPU unit A2ACPUR21
Input and output points: 512 points. Inp