LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Manual Download
MITSUBISHI A0J2E-E56DR User's Manual PDF
Product model: A0J2E-E56DR
Name: Input/Output Module
Brand: MITSUBISHI
Sort: User's Manual
File language: English
MELSECNET/10.
Inter-PC fiber loop. Cable length: 5 meters.
Long distance CPU extension cable.
For QnA/ACPU/ motion control and GOT connection. Input type: DC input, positive common end A0J2E-E56DR PDF.
Input points: 16 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/5mA.
External connection: 4 wire.
Fast connector type.
Simple wiring through quick connector A0J2E-E56DR
Can be installed along the 6 direction.
MITSUBISHI PLC program simulation debugging
The basic idea of program simulation debugging is,
In order to facilitate the form of simulation to generate the actual state of the scene,
Create the necessary environmental conditions for the operation of the program A0J2E-E56DR PDF.
Depending on the way the field signals are generated,
The simulation debugging has two forms of hardware simulation and software simulation. Enter 8 points.
7mA DC24V.
Response time: 12ms.
8 positive, 1 public to reduce the public in common use A0J2E-E56DR PDF.
Output 8 points.
DC24V/AC240V, 2A/1 point, 8A/1 commoon A0J2E-E56DR Manual.
Response time: 12ms.
8 point 1 public 20 point terminal.
PLC is introduced by the relay control technology after the development of micro processing technology,
Can be easily and reliably used for switching control MITSUBISHI User's Manual.
As the analog quantity can be converted into digital quantity, the number of digital quantity is just a number of switching value,
Therefore, after the conversion of analog, PLC can also be reliable for processing control.
Because the continuous production process often has the analog quantity, the analog quantity control is sometimes called process control MITSUBISHI User's Manual.
Analog quantity is not electricity, and PLC can only handle digital quantity, quantity of electricity.
All to realize the conversion between them to have the sensor, the analog quantity into a number of power.
If this power is not standard, but also through the transmitter,
The non-standard power into a standard electrical signal, such as 1-5V, 4-20mA, 0-10V, etc MITSUBISHI User's Manual. .
At the same time, there is also an analog input unit (A/D),
Transform these standard electricall signals into digital signals,
The analog output unit (D/A), in order to transform the digital quantity after PLC processing into analog quantity -- standard electric signal A0J2E-E56DR User's Manual.
So the standard telecommunication number, the conversiion between the number of operations to use a variety of computing A0J2E-E56DR Manual.
This requires the resolution of the analog unit and the standard electrical signal.